Rapidrop wet alarm valve pdf

In the event of variable pressure condition, false alarm. When a fire alarm sounded, one fireman from each group. Rapidrop is proud to have worked on prestigious projects around the globe. A hinged clapper remains open with water flowing in one direction, and automatically closes when flow stops preventing backflow. Gw sprinklers products have been helping to protect people, property and the environment from fire for over sixty years. The alarm check valve is designed to initiate an alarm during a sustained flow of water by operating an optional water motor alarm andor a pressure switch. Groove x groove, flange x flange, flange x groove alarm valves are divided seat ring, rubberfaced clapper, check type, water flow alarm valves.

Modular package with ul listed rapidrop deluge valve downstream, upstream and bypass butter. Rapidrop 201f valve specifications rapidrop valves. Alarm and control valves including wet, dry, deluge and pre action with both flanged and grooved connections. This type of wet alarm valve is designed to automatically initiate electric or hydraulic alarm whenever there is a flow of water to one or more sprinklers. In this demonstration we will be covering the repair of the rubber replacement of the viking model j1 alarm check valve. Fire fighting gate valve, butterfly valve, drv, nrv, check valve. Alarm valve includes trim packages valves, gauges, pressure switch, fittings and nipples to provide retard chamber connection,drain connections and alarm test bypass. This trim is supplied with the sprinkler alarm bell, which. To eliminate the need to empty water remaining in the standpipe after use, a drain. Today the company develops, manufactures and distributes a wide range of stateoftheart water control and delivery devices for. This website uses cookies to improve your experience.

Wet alarm valve assembly for fire sprinkler system. Hover over the scrolling images to discover some of our largest projects and their location. Optional upstream and downstream pressure taps included on select sizes. External bypass prevents false alarm under all supply pressure condition. Rapidrop model d wet alarm valves are designed for use in wet pipe sprinkler installations in buildings not subject to freezing temperatures. The range includes approvals from fm, ul, lpcb, ce. Model b wet alarm valve lpcb approved data sheet 5. The viking model j1 alarm check valve serves as a check valve by trapping pressurized water above the clapper and preventing reverse flow from sprinkler piping. Deluge valve model h ul listed rapidrop global rutland business park, newark road, peterborough, pe1 5wa, united kingdom. Automatically actuates electrically andor hydraulically operated. Download datasheet or contact manufacturer to make product inquiries.

The alarm check valve is a water flow alarm device designed for vertical installation in the main supply to a wet pipe sprinkler system, across the uae, dubai, the mena region and qatar. Bureau veritas maritime approval style 751 and style 752. Automatic sprinkler, water spray and deluge systems. Find rapidrop brand suppliers in qatar with online qatar oil and gas directory. Rapidrop global limited is the leading uk manufacturer of fire sprinkler system products. Rapidrop brand products suppliers, providers in doha, qatar rapidrop description. Victaulic series 751 firelock alarm check valve alarm. Rapidrop rapidrop global limited, a uk based manufacturer of fire sprinkler system products with international sales and distribution serving the needs of the fire detection and suppression industry. The seat is tinned to prevent the rubber clapper facing from sticking. Rapidrop alarm valve model c is a double seated clapper check valve with grooved seat design which ensures positive water flow for alarm operation and is designed for installation in wet pipe sprinkler system. Viking wet pipe alarm check valve system system reset procedure. Easypac commercial riser assemblies 114 8 dn32 dn200 technical data sheet. Definitions and preferred nomenclature 21 wetbarrel hydrants 21. While using a deluge valve in the wet pilot system.

System sensors line of pressure switches includes the eps10 series for use in wet, dry, deluge, and preaction automatic sprinkler systems to indicate a discharge from a sprinkler. Rapidrop sprinkler equipment has been installed all around the world from london. Alarm valve is a double seated clapper check valve with grooved seat design, which ensures positive water flow for alarm operation and is designed for installation in wet pipe sprinkler system. Typical service is for inline fire protection control. Single interlock systems release water into the pipes when a fire alarm triggers. Deviations from these standards will invalidate warranty. Because of fire sprinkler or test valve activation, the indicator detects water flow and transmits signal to control system. Rapidrop model b wet alarm valves are designed for use in wet pipe sprinkler installations in buildings not subject to freezing temperatures. Rapidrop model e wet alarm valves are designed for use in wet pipe sprinkler installations in buildings not subject to freezing temperatures. The eps40 and eps120 series supervisory pressure switches are intended for dry pipe systems or pressure t anks and water supplies of automatic water control valves.

An alarm valve prevents a reverse flow of water from the installation into the firepump room, but in case a fire sprinkler is activated opened due. Victaulic is a leading fire protection manufacturer of innovative fire products and fire fighting systems including sprinklers, fire extinguishing and fire suppression systems, pipe couplings and fittings, and flow control valves. Rapidrop sprinkler equipment has been installed all around the world from london to new york to. The valve is designed to initiate an alarm during a sustained flow of water such as the flow required by an open sprinkler by operating an optional water. Sprinkler system animation alarm valve activated youtube. Grooved swing check valve, 350 psi24 bar rated, ul, fm flanged swing check valve, 350 psi24 bar. Water flow pressure switches, supervisory pressure. No statement contained herein concerning a possible or suggested use of any material, in pdf format on our website at. Cvf 300 resilient seat check valve is a rubber faced, flanged swing type check valve that allows water flow in one direction only. Rapidrop bdn100 wet alarm valve is designed for use in wet pipe sprinkler installations in buildings not subject to freezing temperatures. Subscribe to our newsletter stay updated with the latest trends and technologies in the fire protection industry. The valve is opened when a fire alarm that may monitor smoke or flame sensors triggers.

For installation instructions with european trim download for installation instructions with fm trim download. J1 wet alarm valve with eurotrim for the sweden market. Removable cover allows easy access for inspection and maintenance. Test the sprinkler alarm bell or electric alarm by turning the alarm test valve to the test position. The av0 alarm check valve trim includes pressure gauges to monitor system pressure conditions, a bypass check valve, a main drain valve, and an alarm test valve. Rapidrop global limited is the leading uk manufacturer of fire. Full project lists can also be downloaded by country and sector below. Alarm check valve is designed to allow the installation of pressure switches to activate electric alarms and control panels when a sustained flow of water such as an open sprinkler causes the alarm checks clapper to lift from its seat. The wet alarm valve is designed for applications where the water is unlikely to freeze. Preaction systems are a combination of wet, dry, or deluge systems, and require two separate triggers to release water. Cvf300 resilient seat swing check valve flanged rapidrop.

Rapidrop brand products suppliers, providers in doha, qatar. Waterflow detectors waterflow detectors are available for installation on the riser. The water staying pressurized in the pipes is released. Detailed technical specifications of the rapidrop 201f valve, one of over 581 valves in our catalog. Valve body cast with arrow indicator to assist with proper valve orientation. Viking model j1 alarm check valve rubber replacement kit. Wet alarm valve arrangement with bypass 3d warehouse. This type of wet alarm valve is designed to automatically initiate electric or hydraulic alarm whenever there is. These products are used in commercial, infrastructure and industrial applications to protect people and property. The rapidrop range also extends to pump room equipment. Alarm valve is a double seated clapper check valve with grooved seat design. For use in wet pipe automatic sprinkler fire protection systems. Firelock alarm check valve series 751 installation poster. Model e wet alarm valve grooved grooved sizes 80mm to 200mm 3 to 8, fm approved, ul listed, lpcb, ce, gost.

Fire protection butterfly valves iron ulfm lug and wafer butterfly valves are for onoff operation. Explore worldwide projects rapidrop have worked on by country and sector. Alarm gongs optional retard chamber wet alarm valves fm ce, ul, fm, apsad. For more information about how your data is handled, see our privacy policy. Av1 alarm valves may be installed vertically or horizontally. Bureau veritas maritime approval series 751 firelock and 752 retard chamber. Pressure relief reducing valve fm 8 product range dry barrel hydrant with duck foot bend model rdfm1510 size 514 fm approved wet pillar hydrant available. Rapidrop model bde wet alarm valve important installation information rapidrop model b, d, e wet alarm valves must only be installed by a competent person in accordance with requirements of the local authority having jurisdiction. Fivalco gate valves gvosy1161250 flanged pn16 ul 3.

271 1119 1238 956 1494 1637 771 1363 1625 64 1246 107 344 640 200 1589 913 1675 494 1093 996 325 277 1381 619 1484 1026 1408 1372 930 1221 958 734 594 347 823 455 300 1271